SUDOSCAN in Intradialytic hypotension

Share on facebook
Share on twitter
Share on linkedin

SUDOSCAN in Intradialytic hypotension

Electrochemical skin conductance by SUDOSCAN:
a new tool to predict intradialytic hypotension

Pauline Reach, Maxime Touzot, Yannis Lombardi, Catherine Maheas, Emmanuelle Sacco, Audrey Fels, Hélène Beaussier, Pablo Ureña-Torres, Gilles Chatellier, Christophe Ridel, Mathieu  Zuber.
Article title: Electrochemical skin conductance by Sudoscan®: a new tool to predict intradialytic hypotension.
Nephrology Dialysis Transplantation, gfab183.

P. Reach et al from Groupe Hospitalier Saint-joseph, Paris, France, investigated the clinical utility of SUDOSCAN in the prediction of intradialytic hypotension (IDH), a complication in hemodialysis (HD) patients associated with multiple risk factors including cardiac dysfunction and alterations of the peripheral autonomic nervous system.
The identification of patients at risk of intradialytic hypotension, could help clinicians to tailor a more personalized dialysis therapy.

This prospective monocentric study was conducted on 176 hemodialysis patients (64 ±14 years old) over a 6-month period. Dysautonomia was assessed by the measurements of hand and foot Electrochemical Skin Conductance (ESC) using SUDOSCAN, before hemodialysis.

The primary end point was the incidence of intradialytic hypotension (NKF/K-DOQI definition), according to the presence of a pathological hand and/or foot ESC value, during the 3-month study period (see Graphical abstract  below).

As results, mean pre-dialysis hand and foot ESC were 45±20 µS and 54±22 µS, respectively. 35 and 40 % of patients had a pathological ESC at the hand and foot, respectively. Intradialytic  hypotension (IDH) occurred in 46 patients. Logistic regression showed that pathologic pre-hemodialysis hand ESC was associated with an increased risk of IDH [OR=2.56, IC95% (1.04-6.67), p= 0.04]. The cumulative risk incidence of IDH during the study was 5.65 [IC95% (2.04-15.71), p=0.001]
and 3.71 [IC95% (1.41-9.76), p=0.008], with a pathological hand and foot ESC, respectively.

Conclusion: a pathological hand electrochemical skin  conductance (ESC), as assessed by a non-invasive SUDOSCAN test is associated with an increased risk of intradialytic hypotension.

Graphical abstract:

 
Key words: dialysis, electrochemical skin conductance, intra-dialytic hypotension, Sudoscan®
 
 

 

Impeto Medical

Impeto Medical

About SUDOSCAN

SUDOSCAN is a quick and non-invasive test that provides an accurate evaluation of sweat gland function reflecting the status of the autonomic nervous system.

With quantitative and reproducible results, SUDOSCAN allows physicians to detect early and follow-up peripheral neuropathy to monitor disease progression and assess treatment efficacy for better patient management.

SUDOSCAN efficacy has been evaluated in the assessment of small fiber neuropathies in several diseases and compared to reference tests recommended in guidelines.

Recent Posts